Contact us

LiPol is a Leading 3.7V Rechargeable LiPo Batteries Manufacturer, Over 30 Years of Rechargeable LiPo Batteries Expert, Competitive Price with High Quality, Flexible Dimensions High Energy Density, Accept small sample order & custom dimensions, Leading Designer and Manufacturer from China in Lithium-Ion Polymer Battery Cell & Packs, with OEM & ODM Great Services.

Leave your requirement in the below footer box, we will reply within 12 hours.

We have thousands of models with LiPo batteries in stock, we can not put every model on our website and inventory changed every day, pls contact us before your consideration, we can offer you the recommendation.

 

Certificated IEC62133 of LiPo Battery – LiPol Battery Co., Ltd

From 1st May 2012, the LiPo cells and LiPo Batteries must be fully tested to IEC 62133 for CB certification.

About the IEC62133 Standard

IEC62133 is the most important standard for exporting LiPo Batteries, including those used in IT Equipment, tools, laboratory, household, and medical equipment.

In December 2012, the International Electrotechnical Commission (IEC) officially released the IEC62133 second edition IEC62133:2012 (2nd Edition), an international safety standard for LiPo battery products. This standard is mainly for the safety requirements of single LiPo cell batteries and LiPo battery packs and portable sealed single cell batteries and LiPo battery packs containing alkaline or non-acid electrolytes (including LiPo Batteries which is lithium polymer batteries, lithium ion(Li-Ion) cells, nickel-hydrogen batteries, nickel-cadmium batteries, etc.).

The  second edition will have some very significant changes related to LiPo Batteries.

Part I: Cells

The second edition of IEC62133 have the most impact on lithium ion cell manufacturers and dealers, it also important for company who use the lithium ion cell. The changes related to LiPo cells fall into three categories:

       •  Cancel redundant tests with other standards

       •  Modify existing tests

       •  Completely new requirements

1.Cancel redundant tests with other standards

The main focus is to delete the items covered by the United Nations Manual Of Tests and Criteria(UN38.3). The tests deleted are:

Vibration

Mechanical Shock

Low Pressure(Altitude Simulation)

Cell Protection Against High Rate Charging(not a UN38.3 test)

2.Modify existing tests

The most important of these changes is related to how the sample is prepared for testing. In the first edition of the standard, samples were charged at room temperature (20°C ±5°C) according to the manufacturer’s recommended charging method. The second edition includes two charging processes: one at room temperature, and one new program at high and low specified operating temperature ranges (10°C and 45°C if not stated). The new charging method also requires charging at the maximum rated charge current of the product. This process only requires samples at the cell level for short circuits, thermal abuse, crushing, and forced internal short tests.

In the constant voltage test, a continuous low-rate charge test was corrected to a constant charge. This modified test requires the LiPo battery to be charged for 7 days at the manufacturer’s recommended charge current and voltage limits.

Modifications to the crush test included clarification of the test, indicating that the crushing only needs to be done along the broadside of the cell. In addition, termination criteria for 10% deformation of cells were also added.

A more important change is to divide the short circuit into separate parts of the LiPo batteries. The second version of the cell was modified to contain only one test temperature and provide a more stringent range of circuit resistances.

3.Completely new requirements

The most significant change in the second edition is the addition of a new test——Forced Internal Short Circuit test. The test procedure very explicitly describes a method that requires the test facility to fully charge a Li-Ion cell, then open it and remove the jellyroll. Once the cell is removed from the can, a small Nickel particle of a specific shape and size is to be place in a very specific location of the cell jellyroll. Following the placement of the particle, the affected jellyroll is to be crushed. 

Pate II: Batteries

For LiPo battery manufacturers, the IEC62133 edition2 proposal will have less impact on LiPo batteries manufacturers than LiPo battery suppliers. LiPo  Batteries manufacturers’ testing and demand will actually be reduced. The changes related to LiPo batteries fall into three categories:

      •  Revised Charging Procedure

      •   Reduced Sample Requirement

      •   New testing

1.Revised Charging Procedure

Similar to the cell level charging process changes, the LiPo battery level will have a modified charging process, but this will only affect the battery level of a test. This change comes from Japan’s lithium-ion battery and battery test requirements, and it state that samples used for short-circuit testing must be charged in an environment which is equal to the ambient temperature upper and lower: assumes 45°C and 10°C if not provided by the manufacturer. All other tested units on the LiPo battery level were charged at room temperature (20°C).

2. Reduced Sample Requirement

The subcommittee’s test requirements for LiPo batteries are more comprehensive than ever. Therefore, the amount of test required by IEC 62133 at the LiPo battery level has dropped significantly. The testing that has been completely removed as a result of this review is:

•  Vibration

•  Temperature Cycling

•  Mechanical Shock

The result is that the change reduces the required number of samples for testing from 31 for First Edition testing to 21 for Second Edition testing.

3.New Test

A new test has also been added to the LiPo battery level, designed to simulate the LiPo battery charging time longer than the manufacturer’s use of a higher charging rate. This test is performed on a fully discharged five LiPo battery packs, and the charge the batteries with a current of two times the rated current, and an upper voltage limit that is set to the maximum voltage available from the charger to the LiPo battery. If you do not know the charger’s maximum voltage, 5 volt per cell (or cell string) will be used. The current is maintained until the maximum charge voltage is reached and the temperature is monitored during the test. The termination of the test is defined as the temperature is stable, the highest voltage is reached, with acceptance criteria of no fire and no explosion.

LP403035 420mAh IEC62133 Test report

General product information

This LiPo battery is constructed with one pouch cell, and has over-discharge, over current and short-circuits proof circuits.

The main features of the cell in the LiPo battery pack as shown as below:

Model

Nominal capacity

Nominal Voltage

Nominal Charge Current

LP403035

420mAh

3.7V

210mA

Nominal Discharge Current

Maximum Charge Current

Maximum Discharge Current

Maximum Charge Voltage

Cut-off Voltage

210mA

420mA

420mA

4.25V

3V

Tests Performed(name of test and test clause):

Tests are made with number of samples specified in Table 2 of IEC62133:2012(2nd Edition).

Test items:

Type test conditions

Charging procedures for test purpose

Continuous charging at constant voltage(cells)

Moulded case stress at high ambient temperature(LiPo battery)

External short circuit(cell)

External short circuit(LiPo battery)

Free fall

Thermal abuse(cells)

Crush(cells)

Over-charging of LiPo LiPo battery

Forced discharge(cells)

Transport tests

Test conclusion:

LiPo Battery submitted by LiPol Battery Co.,Ltd are tested according to IEC62133: 2012(2nd Edition) Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed seconds cells. and for batteries made from them, for use in portable applications.

Test result: Pass.

IEC62133: 2012(2nd Edition)

Clause

Requirement – Test

Verdict

4

Parameter measurement tolerances

P

5

General safety considerations

P

Cells and batteries subject to intended use be safe and continue to function in all respects

P

Cells and batteries subject to reasonably foreseeable misuse do not present significant hazards

P

5.2

Insulation and wiring

P

Internal wiring and insulation are sufficient to withstand maximum anticipated current, voltage and temperature requirements

P

Orientation of wiring maintains adequate creep age and clearance distances between conductors. Mechanical integrity of internal connections is sufficient to accommodate conditions of reasonably foreseeable misuse.

P

5.3

Venting

P

Battery cases and cells incorporate a pressure relief mechanism or are constructed so that they relieve excessive internal pressure at a value and rate that will preclude rupture, explosion and self-ignition.

P

Encapsulation used to support cells within an outer casing does not cause the battery to overheat during normal operation no inhibit pressure relief.

P

5.4

Temperature/voltage/current management

P

The batteries are designed such that abnormal temperature rise conditions are prevented.

P

Means is provided to limit current to safe levels during charge and discharge.

P

The batteries are designed such that within temperature, voltage and current limits specified by the cell manufacturer.

P

Batteries are provided with specifications and charging instructions for equipment manufacturers so that associated chargers are designed to maintain charging within the temperature, voltage and current limits specified.

P

5.5

Terminal contacts

P

Terminals have a clear polarity marking on the external surface of the battery

P

The size and shape of the terminal contacts ensure that they can carry the maximum anticipated current.

P

External terminal contacts surfaces are formed from conductive materials with good mechanical strength and corrosion resistance.

P

Terminal contacts are arranged to minimize the risk of short circuits.

P

5.61

Protective circuit components are added as appropriate and consideration given to the end-device application

P

5.6.2

Design recommendation for lithium system only

P

For the battery consisting of a single cell or a single cellblock:

-charging voltage of the cell does not exceed the upper limit of the charging voltage specified in Clause 8.1.2, Table 4: or

P

-Charging voltage of the cell does not exceed the different upper limit of the charging voltage determined through Clause 8.1.2, NOTE1.

P

5.7

Quality plan

P

The manufacture has prepared a quality plan defining the procedures for the inspection of materials , components, cells and batteries and which covers the process of producing each type of cell and battery.

P

6

Type test conditions

P

Tests were conducted with the number of cells or batteries as outlined in Table 2 of IEC62133 with cells or batteries that were not more than six months old.

P

Unless noted otherwise in the test methods, thieving was conducted in an ambient of 20°C±5°C.

P

8

Specific requirements and tests

P

8.1

Charging procedure for test purposes

P

If a cell’s specified upper and/or lower charging temperature exceeds values for the upper and/or lower limit test temperatures of Table 4, the cells were charged at the specified values plus 5°C for the upper limit and minus 5°C for the lower limit.

P

A valid rationale was provided to ensure the safety of the cell(see Figure A.1)

P

8.2

Intended use

P

8.2.1

Continuous charging at constant voltage(cells)

P

Fully charged cells are subjected for 7 days to  a charge as specified by the manufacturer.

P

Results: No fire, no explosion, no leakage

P

8.2.2

Moulded case stress at high ambient temperature(battery)

P

Fully charged batteries according to the first procedure in 8.1.1, the batteries were placed in an air-circulating oven at a temperature of 75°C±2°C for 7 hours. Afterwards, they are removed and allowed to return to room temperature.

P

8.3

Reasonably foreseeable misuse

P

External short circuit(cell)

P

The case temperature declined by 20% of the maximum temperature rise

P

8.3.2

External short circuit(battery)

P

The batteries were tested until not of the following occurred:

-24 hours elapsed

P

8.3.3

Free fall

P

Ambient temperature of 20°C±5°C.

P

Fully charged cells or batteries were dropped 3 times from a height of 1.0m onto a concrete floor.

P

After the test, the cell or battery shall be put on rest for a minimum of one hour and then a visual inspection shall be performed.

P

Results: No fire, no explosion

P

8.3.4

Thermal abuse(cells)

P

The cells were held at 130°C±2°C for:

-10 minutes

Results: No fire. No explosion

P

8.3.5

Crush(cells)

P

Each fully charged cell, charged according to the second procedure at the upper limit charging temperature in 8.1.2, is immediately transferred and crushed between two flat surfaces in an ambient temperature.

P

The crushing force was released upon:

-The maximum force of 13 kN ±1 kN has been applied.

Results: No fire. No explosion

P

8.3.6

Over-charging of battery

P

Test was continued until the temperature of the outer casing:

-Reached steady state conditions(less than10°C charge in 30 minute period); or

-Returned to ambient

Results: No fire. No explosion

P

8.3.8

Transport test

P

Regulations concerning international transport of LiPo batteries are based on the UN Recommendations on the Transport of Dangerous Goods. Testing requirements are defined in the UN Manual of Tests & Criteria.

Testing laboratory

P

9

Information for safety

P

The manufacturer of secondary cells ensures that information is provided about current, voltage and temperature limits of their products.

P

The manufacturer of batteries ensures that equipment manufacturers and, in the case of direct sales, end-users are provided with information to minimize and mitigate hazards.

P

10.2

Battery marking

P

Batteries marked in accordance with the requirements for the cells from which they are assembled.

P

Batteries marked with an appropriate caution statement.

P

11

Packaging

P

Cells or batteries were provided with packaging that was adequate to avoid mechanical damage during transport, handing and stacking. The materials and pack design was chosen to prevent the development of unintentional conduction, corrosion of the terminal and ingress of moisture.

P

Certificated IEC62133-2017 LiPo Batteries

3.7V Rechargeable LiPo Batteries Manufacturer Supplier, IEC62133 certificated lithium polymer batteries for your new device, LiPol Custom-shaped batteries are designed to fit into any and all spaces in a product. In order to provide the best efficiency, LiPo batteries can be made to fit into even unused spaces. We provide Custom LiPo Batteries, semi-custom LiPo Batteries, and off-the-shelf LiPo Batteries. With our proprietary formula and high discharge-rate technology, you can maximize the run time and use of your product. we are the industry-leading manufacturer of shaped LiPo batteries. 

We design and manufacture custom Lithium Polymer Batteries’ packs to customers’ specifications. If you need a specific Lithium Polymer Batteries pack, we can advise the best possible solution, Customized Your Lithium Polymer Battery in Any Size, Capacity, and Shape, Meet Your Different Needs by Assembling the Lithium Polymer Battery in Series and Parallel.

 

IEC62133 Certificated 320mAh LP572225 LiPo Battery

IEC62133 Certificated 320mAh LP572225 LiPo Battery

IEC62133 Certificated 320mAh LP572225 LiPo Battery With PCM & 10k NTC and wires 50mm and connector Model CB Certificated LP422533 300mAh LiPo Battery Type Rechargeable LiPo battery Capacity 300mAh LiPo Battery Voltage 3.7V LiPo Battery Energy 1.11Wh LiPo Battery...

RoHs Certificated LP604260 2000mAh LiPo Battery

RoHs Certificated LP604260 2000mAh LiPo Battery

RoHs Certificated LP604260 2000mAh LiPo Battery With PCM and wires 50mm and connector Model RoHs Certificated LP604260 2000mAh LiPo Battery Type 3.7V Standard LiPo Battery Capacity 2000mAh Standard LiPo Battery Voltage 3.7V LiPo Battery Energy 7.4Wh LiPo Batteries Net...

CB Certificated LP422533 300mAh LiPo Battery

CB Certificated LP422533 300mAh LiPo Battery

CB Certificated LP422533 300mAh LiPo Battery With PCM & wires 50mm and connector Model CB Certificated LP422533 300mAh LiPo Battery Type Rechargeable LiPo battery Capacity 300mAh LiPo Battery Voltage 3.7V LiPo Battery Energy 1.11Wh LiPo Battery Net Weight 6 g...

LP502025 180mAh 3.7V Rechargeable LiPo Battery Batteries with connector JST SHR-02V-S-B A

LP502025 180mAh 3.7V Rechargeable LiPo Battery Batteries with connector JST SHR-02V-S-B A

LP502025 180mAh 3.7V Rechargeable LiPo Battery Batteries with connector JST SHR-02V-S-B A With PCM & wires 50mm Model LP502025 180mAh 3.7V Rechargeable LiPo Battery Batteries with connector JST SHR-02V-S-B A Type 3.7V LiPo battery Capacity 180mAh LiPo Battery...

LP351738 180mAh 3.7V Rechargeable LiPo Battery

LP351738 180mAh 3.7V Rechargeable LiPo Battery

LP351738 180mAh 3.7V Rechargeable LiPo Battery Batteries With PCM & wires 50mm Model LP351738 180mAh 3.7V Rechargeable LiPo Battery Batteries Type 3.7V LiPo battery Capacity 180mAh LiPo Battery Voltage 3.7V LiPo Battery Energy 0.67Wh LiPo Battery Net Weight 3 g...

LP902358 1280mAh 3.7V Rechargeable LiPo Battery with connector JST ZHR-3 B

LP902358 1280mAh 3.7V Rechargeable LiPo Battery with connector JST ZHR-3 B

LP902358 1280mAh 3.7V Rechargeable LiPo Battery with connector JST ZHR-3 B With PCM &  wires 50mm & JST ZHR-3 B Model LP902358 1280mAh 3.7V Rechargeable LiPo Battery with connector JST ZHR-3 B Type Rechargeable LiPo battery Capacity 1280mAh LiPo battery...

LP571225 200mAh IEC62133 Certificate LiPo Batteries Manufacturer

LP571225 200mAh IEC62133 Certificate LiPo Batteries Manufacturer

LP571225 200mAh IEC62133 Certificate LiPo Batteries Manufacturer With PCM & wires 50mm  Model LP571225 200mAh IEC62133 Certificate LiPo Batteries Manufacturer Type 3.7V LiPo battery Capacity 200mAh Voltage 3.7V Energy 0.74Wh Net Weight 5 g Detail Protection...

LP501522 200mAh 3.7V LiPo Batteries with connector Molex 78172-0003

LP501522 200mAh 3.7V LiPo Batteries with connector Molex 78172-0003

LP501522 200mAh 3.7V LiPo Batteries with connector Molex 78172-0003 With PCM & wires 50mm & Molex 78172-0003 Model LP501522 200mAh 3.7V LiPo Batteries with connector Molex 78172-0003 Type 3.7V LiPo battery Capacity 200mAh Voltage 3.7V Energy 0.74Wh Net Weight...

LP683048 1120mAh CB Certificate LiPo Batteries with connector JST SUHR-03V-S-B

LP683048 1120mAh CB Certificate LiPo Batteries with connector JST SUHR-03V-S-B

LP683048 1120mAh CB Certificate LiPo Batteries with connector JST SUHR-03V-S-B With PCM &  wires 50mm Model LP683048 1120mAh CB Certificate LiPo Batteries with connector JST SUHR-03V-S-B Type Rechargeable LiPo battery Capacity 1120mAh Voltage 3.7V Energy 4.14Wh...

LP804050 1700mAh IEC62133 Certificate LiPo Batteries Manufacturer

LP804050 1700mAh IEC62133 Certificate LiPo Batteries Manufacturer

LP804050 1700mAh IEC62133 Certificate LiPo Batteries Manufacturer With PCM &  wires 50mm Model LP804050 1700mAh IEC62133 Certificate LiPo Batteries Manufacturer Type Rechargeable LiPo battery Capacity 1700mAh Voltage 3.7V Energy 6.29Wh Net Weight 34 g Detail...

Get In Touch

Get answer before you buy LiPo Batteries. Whether a quote or a specification request from our LiPol battery section, We do not provide telephone support, the reason being that it is impossible to offer a quality product at an attractive price or answer your questions without making some compromises. We have decided to compromise on human resources rather than the technical.

Fill out my online form.